E.M.GROUT-C

NON-SHRINK CEMENT BASED GROUTING MORTAR

DESCRIPTION

E.M.GROUT-C is a non-shrink cementitious ready-mix grout with 65 MPa compressive strength. Due to the special combination of E.M.GROUT-C, It is useful for filling and grouting of base plates in steel frame buildings and installation of heavy machinery.

It meets the requirements of the following standard:

ASTM C1107

E.M.GROUT-C

SURFACE PREPARATION

Surfaces should be clean sound and free from oil, grease, laitance and loose particles. Metal surfaces should also be clean and free of rust, oil, grease and contaminants.

The prepared areas should be flooded with water prior to the placement of ABAGROUT-C2 before the grout is placed. All free water should be released from the area to be grouted. There should be NO standing water present when the grout is placed.

 

MIXING

ABAGROUT-C2 should be mixed using a suitable mixer. For flowable consistency use a band drill and paddle with a speed of <400 R.P.M. For large works use a high shear vane grout mixer. (Drum mixers are not recommended).

The entire contents of the bag should be added to the pre-measured (2.75-3.50 litres) water while mixing.

DO NOT add more than the maximum water content.

 

APPLICATION

Ensure the substrate is prepared according to the manufactures recommendations. NO free water should be present in the area to be grouted. Ensure that there are sufficient air release holes for entrained air to escape.

Mortar should be continuously poured, from one side only, until the gap is completely filled. Maintain continuous head of grout when pouring.

 

CURING

It is necessary to cure exposed areas of grout with humidified method for at least 7 days.

  • Suitable for static loads
  • Without hardening crake
  • Non shrinkage
  • Controlled expansion
  • Premixed grout requires only the addition of mixing water on site
  • Excellent flowability
  • High early strength and fast loading capability

  • Ensure the substrate is prepared according to the manufactures recommendations. NO free water should be present in the area to be grouted. Ensure that there are sufficient air release holes for entrained air to escape.
  • Mortar should be continuously poured, from one side only, until the gap is completely filled. Maintain continuous head of grout when pouring.
  • Filling and grouting of base plates in steel frame buildings
  • Installation of heavy machinery
  • Installation precast columns
  • Anchor bolts
  • All areas requiring grouting

Physical state

 Powder

Color

 Grey

Water by weight of grout

 11 - 14 %

Specific gravity of fresh mortar

 2.35 ± 0.1 g/cm³

Chloride ion

 No Chloride content

STORAGE

  • Shelf life: 1 year in the original package.
  • Storage condition: should be protected from direct sunlight and moisture.
  • Keep bag in the temperature range between +10°C and +30°C.
  • Packing: 25 kgs bags.

 

 

HEALTH AND SAFETY

  • This product does not contain any substances hazardous to human health and the environment. However, it should not be swallowed and contact with skin and eyes. In case of contact with
  • eyes, rinse immediately with plenty of water. E.M.GROUT-C is not flammable.
  • For further information refer to the material safety data sheet.  MSDS is available at ABADGARAN website.

 

WE DEVELOP CHEMISTRY