DOSAGE
The optimum dosage of A.C.P-F can be determined by trials in the site.
Depending on concrete mix design (concrete type, workability, compressive strength, sizes and types of aggregates, cement content, water/cement ratio, ambient temperature and concreting conditions), a dosage of between 5.0 and 9.0 percent by weight of cement is recommended.
Note: when using A.C.P-F, water-cement ratio must be considered around 0.40.
For use with other range of dosage, contact ABADGARAN Technical Services Department.
Please contact our engineering office in case of simultaneously use of more than one admixture.
DIRECTION OF USE
A.C.P-F can be added to concrete in two ways:
1-A.C.P-F could be added to ready-mix concrete before placing concrete.
2-A.C.P-F could be added to a part or whole of concrete mixing water then added to the concrete mix.